Introduction

This section describes the purpose and scope of this guide and provides an overview of the ChargePoint®Express Distro Power Link 2000.

About This Guide

This guide describes the routine operational tasks and preventive maintenance activities required to keep the Power Link 2000 operating safely and reliably. It is intended for site operators, facility personnel, and qualified maintenance technicians responsible for day‑to‑day station operation and scheduled maintenance.

Power Link 2000 Overview

Power Link 2000 is a product within the Express DC fast charging platform. Power Link 2000 is a charging dispenser that delivers DC power to EVs through flexible, lightweight charging cables equipped with industry standard connectors such as CCS1, CCS2, CHAdeMO, MCS, and NACSClosed North American Charging Standard. The Power Link 2000 can accommodate up to two charging cables to charge two electric vehicles simultaneously or sequentially.

Power Link 2000 requires input power from a power cabinet. For information on power cabinets and other modular EVSEs in the Express product family, refer to the Express platform documents at ChargePoint Product Reference Documentation.

Cabinet Configurations

The Power Link 2000 is a vertical cabinet that is available in the following variants:

  • Pedestal-Mount Power Link 2000 – Designed for installation on a concrete ground surface. This variant includes charging cable holsters and an interactive display, and is available with either single or dual charging cables.

  • Overhead-Mount Power Link 2000 – Designed for installation on a wall or overhead structure (such as a gantry or ceiling‑mounted support). This variant is also available with either single or dual charging cables.

    Pedestal-Mount

    Overhead-Mount

Charging Cable Type and Quantity

Depending on the charging speed and connectors required, pedestal-mount Power Link 2000s can be installed with one or two liquid-cooled cables (LCCClosed Liquid Cooled Cable) or non-liquid-cooled cables (non-LCCClosed Liquid Cooled Cable). The pedestal-mount Power Link 2000 with LCCClosed Liquid Cooled Cable comes with a liquid cooling system attached to the back of the enclosure.

Pedestal-Mount with Single or Dual LCCClosed Liquid Cooled Cable Pedestal-Mount with Single or Dual Non-LCCClosed Liquid Cooled Cable

Charging Cable Length and Cable Management Kits

Depending on the required cable reach, the pedestal-mount Power Link 2000 can be installed with a standard cable management kit (CMKClosed Cable Management Kit) to manage standard length (up to 5.8 m or 19 ft) charging cables, or with a tall CMKClosed Cable Management Kit or overhead CMKClosed Cable Management Kit to manage medium length (7.6 m or 25 ft) charging cables. The image below shows the CMKClosed Cable Management Kit options installed with a pedestal-mount Power Link 2000.

The CMKs function as follows:

Exterior Parts

The following shows an exterior view of a Power Link 2000 equipped with a standard CMKClosed Cable Management Kit.

Front View

Rear View (non-LCCClosed Liquid Cooled Cable)

Rear View (LCCClosed Liquid Cooled Cable)

Express Solo Exterior Parts

Ref

Part

Ref Part
(a)

Standard CMKClosed Cable Management Kit swingarm, left

(m)

Charging connector, right

(b)

Standard CMKClosed Cable Management Kit mast

(n)

Holster, right

(c)

Charging cable, left

(o)

Lower cover and door (with customizable vinyl)

(d)

Status LED, left

(p)

Tetherball, right

(e)

Area downlight (front – illumination side)

(q)

Status LED, right

(f)

Display/CCOMClosed Control and Communications Module assembly (display side)(*)

(r)

Upper rear cover (non-LCCClosed Liquid Cooled Cable)

(g)

Holster, left

(s)

Lower rear cover (non-LCCClosed Liquid Cooled Cable)

(h)

Side panel (side extrusion), left

(t) Side panel (side extrusion), right
(i)

Charging connector, left

(u)

Tetherball, left

(j)

Standard CMKClosed Cable Management Kit swingarm, right

(v)

Upper rear cover (LCCClosed Liquid Cooled Cable)

(k)

Charging cable, right

(w)

Lower rear cover (LCCClosed Liquid Cooled Cable)

(l)

Upper cover and door (with customizable vinyl)

   

(*) CCOMClosed Control and Communications Module = Communications and Control Module

Interior Parts

The following shows an interior view of the Power Link 2000, with covers and panels removed.

Front View Rear View
Express Solo Interior Parts

Ref

Part

Ref Part
(a)

Smart antenna (option)

(l)

Display/CCOMClosed Control and Communications Module Assembly (CCOMClosed Control and Communications Module side)

(b)

Charging cable assembly, left

(m) Smart Ethernet Switch
(c)

DC Input Power Path Assembly A(*)

(n)

Holsters, interior view

(d)

DC Input Power Path Assembly B(*)

(o)

Lower enclosure door

(e)

Power Link 2000 controller

(p)

Charging cable assembly, right

(f)

Terminal block (48 V DC and soft shutdown switch)

(q)

Coolant reservoir (LCCClosed Liquid Cooled Cable units only)

(g)

Internal fans

(r)

External fan

(h)

Cooling controller (LCCClosed Liquid Cooled Cable units only)

(s)

Ion filter (LCCClosed Liquid Cooled Cable units only)

(i)

Upper enclosure door

(t)

Pump (LCCClosed Liquid Cooled Cable units only)

(j)

Door fan

(u)

Pump controller (LCCClosed Liquid Cooled Cable units only)

(k)

Ethernet switch (SSLANClosed Smart Switch Local Area Network)

(v) LCCClosed Liquid Cooled Cable fans (LCCClosed Liquid Cooled Cable units only)

(*) Each power path assembly consists of a Proton module coupled with input/output bus bars.

 

Product Guides

A full suite of guides is available for Power Link 2000, as summarized below.

Access ChargePoint documents at ChargePoint Product Reference Documentation.

ChargePoint Product Documents

Document

Content

Primary Audiences

Datasheet

Full station specifications

Site designer, installer, and station owner

Site Design Guide

Civil, mechanical, and electrical guidelines to scope and construct the site

Site designer or engineer of record

Concrete Mounting Template Guide

Instructions to embed the charging station template in a concrete pad with anchor bolts and conduit placement (these may also be included in the Site Design Guide)

Site construction contractor

Surface Conduit Entry Kit Guide

Instructions for sites where conduit cannot be run underground

Installer

Construction Signoff Form

Checklists used by contractors to ensure the site is correctly completed and ready for product installation

Site construction contractor

Installation Guide

Anchoring, wiring, and powering on

Installer

Operation and Maintenance Guide

Operation and preventive maintenance information

Station owner, facility manager, and technician

Service Guide

Component replacement procedures, including optional components

Service technician

Declaration of Conformity

Statement of conformity with directives

Purchasers and public