Introduction
This Concrete Mounting Template can be used interchangeably across product lines to properly mount a DC dispenser (charging station) to a concrete pad. Most sites install and run service wiring underground to a concrete pad. Then the charging station is installed on that concrete pad. The Concrete Mounting Template is used to align anchor bolts and conduit openings to ensure correct positioning.
Compatibility
This ChargePoint® Concrete Mounting Template (CMT) can be used interchangeably across product lines to properly mount a DC dispenser (charging station) to a concrete pad.
Purpose of the Concrete Mounting Template
Most sites install and run service wiring underground to a concrete pad. Then the charging station is installed on that concrete pad. The Concrete Mounting Template is used to align anchor bolts and conduit openings to ensure correct positioning.
Concrete Mounting Template Kit Contents
The Concrete Mounting Template kit contains the following:
-
Concrete Mounting Template (CMT) metal template
-
Threaded mounting bolts (x4), 16 mm thread, 305 mm long, with plastic caps on one end
-
M16 nuts (x8)
-
M16 washers (x8)
Order a Template for Every Charging Station/Dispenser
You will need a Concrete Mounting Template for each charging station dispenser.
Risk of Death, Personal Injury, Property Damage, and Voided Warranty
You are required to engage or be a ChargePoint certified installer, and required to use a ChargePoint-approved mounting method, such as this Concrete Mounting Template, to install the ChargePoint charging station.
If you fail to use the approved mounting method, you risk the station tipping over, and that can cause death, personal injury, or property damage, and will void all ChargePoint and other warranties and ChargePoint is not responsible.
You must be a licensed electrician and complete the training at https://www.chargepoint.com/partners/training-certification to become ChargePoint certified.
The number and location of conduits and wiring differ for each installation. Always refer to site drawings for conduit and wiring details.
Surface Conduit Entry Does Not Use CMT (Order Separately)
Do not use this concrete mounting template (CMT) for surface conduit entry. That requires different components.
Before you begin, contact ChargePoint to obtain an approved Surface Conduit Entry kit.