The Express Chip Pedestal is an ancillary terminal that works directly with the Express Plus Power Link DC fast charger to enable credit card chip reading capability when required by law. This topic provides preliminary specifications for the credit card chip reader pedestal. Refer to the datasheet below for more information.

Preliminary Specifications

Station Electrical Input

Input Rating

3-phase, 480Y VAC, 110 A, 60 Hz

Wiring

L1, L2, L3, Neutral, Earth

Station Electrical Output

Max Output Power

80 kW

Output Voltage, Charging

200 to 1000 VDC

Max Output Current

CHAdeMO (North America): 140 A

CHAdeMO (Europe): 125 A

CCS1: 200 A

CCS2: 200 A

Power Modules per Station

2

Paired Station Electrical Output

Paired Max Output Power

160 kW

Paired Max Output Current

CHAdeMO (North America): 140 A

CHAdeMO (Europe): 125 A

CCS1: 250 A

CCS2: 250 A

Power Module

Max Output Power

40 kW

Max Output Current

100 A

Power Conversion Efficiency

Up to 96%

Power Factor

0.99 at full load

Harmonics

iTHD < 5% (Complies with IEEE 519)

Power Module Cooling

Liquid Cooling Technology

Functional Interfaces

Max Connector per Station

Up to two connectors per station

Supported Connector Types

CHAdeMO

CCS1 (SAE J1772™ Combo)

CCS2 (IEC 61851-23)

Cable Length with Swing Arm*

Full Horizontal Reach: 4.27 m (14 ft)

LCD Display

Full-color 254 mm (10 in) display for driver interaction

Top Display

Full-color 508 mm (20 in) LED display for notifications

Authentication

RFIDClosed Radio Frequency IDentification: ISO 15693, ISO 14443, NEMAClosed National Electrical Manufacturers Association EVSEClosed Electric Vehicle Supply Equipment 1.2-2015 (UR)

Tap to Charge (NFC on Apple & Android): 15118-2 (EIMClosed External Identification Means)

Remote: Mobile and in vehicle (if supported by vehicle)

**Horizontal reach to typical vehicle charging port: 3.76 m (12 ft 4 in)

Connectivity Features

Vehicle Safety Communication

CHAdeMO: JEVS G104 over CAN

CCS1: SAE J1772 over PLC

CCS2: IEC 61851-23

Plug-Out Detection

Power terminated per JEVS G104 (CHAdeMO), SAE J2931 (CCS1), and IEC 61851-23 (CCS2)

Local Area Network

2.4 GHz and 5 GHz Wi-FiClosed Wireless Fidelity (802.11 b/g/n)

Wide Area Network

4G LTEClosed Long Term Evolution (fall back to 3G GSM)

Supported Communication Protocols

OCPPClosed Open Charge Point Protocol

Service and Maintenance

Remote system monitoring, diagnostic, and proactive maintenance

Safety and Operational Ratings

Station Enclosure Rating

Type 3R, IP54

Station Impact Rating

IK10

Safety and Compliance

UL and cUL listed: Complies with UL 2202, UL 2231-1, UL 2231-2, CSA 107.1

CE marking: Complies with IEC 62196, IEC 61851

Station Surge Protection

Tested to IEC 6100-4-5, Level 5 (6 kV @ 3,000 A). In geographic areas subject to frequent thunder storms, supplemental surge protection at the service panel is recommended.

EMCClosed Electromagnetic Compatibility Compliance

North America: FCCClosed Federal Communications Commission part 15 Class A

Europe: EN55011, EN55022, and IEC61000-4

Storage Temperature

-40°C to 50°C (-40°F to 122°F)

Operating Temperature

-40°C to 50°C (-40°F to 122°F)

Operational Altitude

< 3,000 m (9,800 ft)

Operating Humidity

Up to 95% at 50°C (122°F) non-condensing

Generic Specifications

Station Enclosure Dimensions

2,413 mm H x 712 mm W x 420 mm D (7'11" x 2'4" x 1'4")

Power Module Dimensions

760 mm H x 430 mm W x 130 mm D (2'6" x 1'5" x 5")

Station Weight (without Power Modules)

250 kg (551 lb)

Power Module Weight

45 kg (98.5 lb)

Energy Management Features

Dynamic Power Management

Allows a fixed maximum power output per station or lets the system dynamically manage the power distribution per station

Remote Energy Management

Manage output power via the ChargePoint Admin Portal, API, and Open ADR 2.0b VEN