Introduction

This section describes the purpose and scope of this guide and provides an overview of the ChargePoint® Express Plus Power Link 2000.

About This Guide

This document describes how to install the Power Link 2000.

This installation guide applies specifically to variation Bpedestal-mount Power Link 2000s. Please note that Power Link 2000 is available in multiple variations and mount types, and installation procedures differ for each.

To ensure this guide is applicable to your unit, verify the part number of your charging station. The part number can be found on the Power Link 2000 package shipping label and is formatted as 99-XXXXXX-YY-ZZ, where:

  • 99-XXXXXX is the base part number

  • YY is a version enumerator

  • ZZ is a variant indicator

Screenshot depicts the procedural step.

This guide is not applicable for certain pedestal-mount Power Link 2000 part numbers. If the Power Link 2000 part number has a base part number and version enumerator that exactly matches one listed below, you must obtain a different installation guide. This is not the correct guide.

  • 99-007902-03

  • 99-007904-03

  • 99-007910-02

  • 99-007911-02

  • 99-007916-02

 

Express Plus Components

Express Plus is a scalable DC fast charging platform that is based on the modular building blocks outlined below.

Express Plus modular building blocks

  1. Power Module: Self-contained AC to DC power conversion system that operates an output of between 100 and 1000 V and delivers up to 40 kW of power.

  2. Power Block: Power cabinet that houses up to five Power Modules and supplies DC output power to Power Link 2000s. Each Power Block can output up to 200 kW of power.

  3. Power Link 2000: Dispenser that delivers DC power to EVs through flexible, lightweight charging cables equipped with industry standard connectors such as CCS1, CCS2, CHAdeMO, MCS, and NACSClosed North American Charging Standard. The Power Link 2000 can accommodate up to two charging cables to charge two electric vehicles simultaneously or sequentially. Built-in cellular networking enables remote management via the ChargePoint Platform Dashboard.

Express Plus System Overview

The Express Plus system consists of the following components:

Power Block

Power Block block diagram:

Labeled diagram of product, tools or parts.

  1. Three phase AC power input

  2. Configurable with up to five 40 kW Power Modules for a maximum total output of 200 kW

  3. Two available HV DCClosed High Voltage Direct Current power outputs (A and B)

  4. 48 V DC power output

  5. Ethernet output

The Power Block is an enclosure structured with an upper and lower enclosure, stacked on a pedestal:

Power Block exterior structure

  1. Upper enclosure: Auxiliary power supply and temperature management components

  2. Lower enclosure: Bay for Power Modules and bus bars to land all input and output cables

  3. Pedestal: Secures the Power Block and provides access for either stub-up or surface mount installations on a concrete pad

Power Link 2000

Power Link 2000 block diagram:

Power Link Block Diagram for power paths, input, output, and 48 V DC

  1. Single or dual HV DCClosed High Voltage Direct Current power paths (A and B)

  2. 48 V DC power input

  3. Ethernet input

  4. Single or dual HV DCClosed High Voltage Direct Current charging cable outputs (L and R)

  5. 48 V DC power output

  6. Ethernet output

The Power Link 2000 is a vertical enclosure that is available in the following variants:

  • Pedestal-Mount Power Link 2000

    This enclosure is designed for mount on a concrete ground surface and is equipped with charging cable holsters and an interactive display. The enclosure is available with single or dual outputs.

    Pedestal-mount Power Link 2000 physical appearance

  • Wall-Mount Power Link 2000

    This enclosure is designed for mount on a wall or other vertical-standing structure. It is equipped with cable holsters and an interactive display. The enclosure is available with single or dual outputs.

    Wall-mount Power Link 2000 physical appearance

  • Overhead-Mount Power Link 2000

    This enclosure is designed for mount on a wall or overhead structure (such as on a gantry or from a ceiling structure). The enclosure is available with single or dual outputs.

    Overhead-mount Power Link 2000 physical appearance

This guide covers installation of pedestal-mount Power Link 2000s. For installation of overhead-mount Power Link 2000s, refer to the Express Plus Overhead-Mount Power Link 2000 Installation Guide, available at ChargePoint Product Reference Documentation.

Power Block to Power Link 2000 Architectures

Express Plus is a highly modular system wherein Power Blocks and Power Link 2000s can be interconnected in many configurations to meet various charging needs, from simultaneous charging of two vehicles at up to 600 kW by a single station to sequential charging of up to 12 vehicles.

The DC output of the Power Block is the DC input of the Power Link 2000. Each Power Block has two HV DCClosed High Voltage Direct Current outputs that can be fed to a single Power Link 2000 or to two different Power Link 2000s. A simplified block diagram of a single Power Block connected to two Power Link 2000s is shown below. The Power Block also feeds 48 V DC power and Ethernet connectivity to the Power Link 2000s.

Block diagram of a single Power Block connected to two Power Link 2000s

In turn, the Power Link 2000 accepts high voltage DC input from up to six Power Blocks. A simplified block diagram of a Power Link 2000 powered by two Power Blocks is shown below.

Block diagram of a Power Link 2000  powered by two Power Blocks

The high voltage DC output, Ethernet, and 48 V DC power output from Power Block(s) can be connected from Power Link 2000 to Power Link 2000, enabling higher port counts in specific sequential charging configurations.

Block showing high voltage DC output from Power Block(s) interconnected from Power Link 2000 to Power Link 2000

The architectures shown above demonstrate only a few of the many supported by Express Plus. The actual architecture for each site will vary depending on the number of stations, the charging capacity required at each charging station, simultaneous or sequential charging requirements, and other criteria. Contact a ChargePoint representative for the ChargePoint‑approved wiring architecture for your specific project. Non-approved wiring between Power Blocks and Power Link 2000s may not enable Express Plus to function as expected.

For full specifications and certifications, refer to the Express Plus Datasheet at ChargePoint Product Reference Documentation.

Pedestal-Mount Power Link 2000 Configurations

The pedestal-mount Power Link 2000 supports multiple configurations to meet diverse installation requirements, as described in this section.

Charging Cables

Depending on the charging speed and connectors required, pedestal-mount Power Link 2000s can be installed with one or two liquid-cooled cables (LCCClosed Liquid Cooled Cable) or non-liquid-cooled cables (non-LCCClosed Liquid Cooled Cable). The pedestal-mount Power Link 2000 with LCCClosed Liquid Cooled Cable comes with a liquid cooling system attached to the back of the enclosure.

Single or Dual LCCClosed Liquid Cooled Cable Single or Dual non-LCCClosed Liquid Cooled Cable

Pedestal Power Link 2000 cable configurations

Cable Management Kit (CMK)

Depending on the required cable reach, the pedestal-mount Power Link 2000 can be installed with a standard CMKClosed Cable Management Kit to manage standard length (5.8 m or 19 ft) charging cables, or with a tall CMKClosed Cable Management Kit or overhead CMKClosed Cable Management Kit to manage medium length (7.6 m or 25 ft) charging cables.

Standard CMKClosed Cable Management Kit Tall CMKClosed Cable Management Kit Overhead CMKClosed Cable Management Kit

Pedestal-mount Power Link 2000 CMK Configurations

Wire Entry

  • Stub-up entry: Wires can enter pedestal-mount Power Link 2000s and Power Blocks through the bottom of the enclosures via conduits or armored cables laid underground.

  • Surface entry: At sites where the wires cannot be laid underground, they can enter into pedestal-mount Power Link 2000s and Power Blocks through the rear side of the enclosures via conduits or armored cables laid above ground.