Wiring Diagrams

These diagrams show wiring for installing single and dual port CP6000 stations on:

  • A dual circuit, dual port

  • A single circuit, dual port

  • A single circuit, single port

The number of dedicated circuits required depends on the type of installation and the power available at the site.

Refer to the CP6000 Datasheet on ChargePoint Product Reference Documentation for electrical input and output specifications.

400/230 VAC Three Phase Dual Circuit, Dual Port

Labeled diagram of product, tools or parts.

(a) L3

(b) L2

(c) L1

(d) Neutral

(e) Main breaker

(f) Neutral bus

(g) Ground bus

(h) Left breaker

(i) Right breaker

(j) Ground

(k) Wire strip length 12 mm (0.5 in)

Labeled diagram of product, tools or parts.

400/230 VAC Three Phase Single Circuit, Dual Port

When using a single circuit to power dual ports, you must connect cables to RCCBs or RCBOs on the right side of the terminal block.

Labeled diagram of product, tools or parts.

(a) L3

(b) L2

(c) L1

(d) Neutral

(e) Main breaker

(f) Neutral bus

(g) Ground bus

(h) Breaker

(i) Ground

(j) Jumper

(k) Wire strip length 12 mm (0.5 in)

Labeled diagram of product, tools or parts.

This configuration can be used either with RCCBClosed Residual Current Circuit Breaker or RCBOClosed Residual Current Breaker with Overload Protection option. Contact ChargePoint Support for guidance and follow the local national regulations.

400/230 VAC Three Phase Single Circuit, Single Port

Labeled diagram of product, tools or parts.

(a) L3

(b) L2

(c) L1

(d) Neutral

(e) Main breaker

(f) Neutral bus

(g) Ground bus

(h) Breaker

(i) Ground

(j) Wire strip length 12 mm (0.5 in)